Shandong Kosman Environmental Technology Co., Ltd. is one of the leading manufacturers and suppliers of membrane separation tertiary vapor recovery unit in China. Please feel free to buy premium equipment for sale here and get pricelist from our factory. All customized products are with high quality and low price.
I. Product Overview
The membrane separation tertiary Vapor recovery unit is a high-efficiency and environmentally friendly device designed to address the problem of Vapor volatilization in gas stations and oil depots. This product employs a combined membrane separation and condensation process, utilizing the differences in permeation rates of different gases through a polymer membrane to achieve highly efficient separation of Vapor from air. The treated exhaust gas meets emission standards, and the recovered liquid oil can be directly reused.
The product complies with the requirements of the "Emission Standard of Air Pollutants for Gas Stations" (GB 20952-2020), with a treatment efficiency ≥95% and an emission concentration ≤25g/m³, making it an excellent choice for gas stations to achieve both environmental compliance and economic benefits.




II. Working Principle
2.1 Core Technology Principle
Membrane separation technology is based on the dissolution-diffusion mechanism: When a mixed gas passes through a polymer membrane under pressure difference, the permeation rates of hydrocarbon VOCs molecules (such as alkanes and aromatics) and inert gas molecules (nitrogen and oxygen) differ significantly, thus achieving selective separation.
Two typical membrane separation mechanisms:
|
Membrane Types |
Separation Mechanism |
Vapor destination: |
Air destination: |
|
Oil/Gas Permeable |
Preferential adsorption and permeation of VOCs |
Permeates through the membrane and returns to the storage tank. |
Intercepted, directly discharged |
|
Oil/Gas Retention |
Preferential air permeation (glass membrane) |
Is trapped and returns to the storage tank. |
Passes through the membrane side, directly discharged |
Glassy oil-gas interception membrane: Above Tg temperature, intercellular chain segment movement exists, increasing free volume and enhancing the membrane's selectivity for hydrocarbon VOCs/air mixtures. Inert gas molecules first dissolve on the membrane surface, then diffuse to the other side of the membrane driven by the concentration gradient, and finally desorb.
2.2 Workflow
The membrane separation + condensation combined process flow is as follows:
Text Oil tank pressure detection (start-up conditions)
↓
Pressure reaches +50Pa → System start-up
↓
Oil gas is extracted by the compressor → Condenser pre-cooling
↓
┌───────────────────┐
│ Membrane separation module separation │
├───────────────────┤
│ Permeate side: Clean air discharge │
│ Residual side: High-concentration oil gas return │
└───────────────────┘
↓
High-concentration oil gas returns to the oil tank → Natural liquefaction
↓
Oil tank pressure drops below -130Pa → System shutdown
2.3 Functions of Core Components
|
Component Names |
Functional Description |
|
Membrane Separation Unit |
Core separation unit, containing a polymer separation membrane, achieves selective separation of oil/gas/air. |
|
Compressor |
It extracts and pressurizes Vapor , providing the pressure driving force for membrane separation. |
|
Condenser |
It pre-cools the Vapor , liquefying and recovering some heavy hydrocarbons, reducing the load on the membrane module. |
|
Gas-Liquid Separator |
It separates condensate from uncondensed gas; liquid oil returns to the tank, while gas enters the membrane module. |
|
Vacuum Pump |
It provides negative pressure to the permeate side of the membrane, increasing the pressure difference across the membrane and improving separation efficiency. |
|
PLC Controller |
Fully automatic control, real-time monitoring of parameters such as pressure and temperature, enabling unattended operation. |
|
Model |
Processing Capacity |
Process Combination |
Start-up Pressure |
Shutdown Pressure |
Power Supply |
Explosion-proof Rating |
|
YQM-8 |
8 m³/h |
Air cooling + membrane separation |
+50 Pa |
-130 Pa |
380V/50Hz |
Ex d IIB T4 |
|
YQM-5 |
5 m³/h |
Membrane separation + condensation |
+50 Pa |
-130 Pa |
380V/50Hz |
Ex d IIB T4 |
|
YQM-10 |
10 m³/h |
Membrane separation + condensation |
+50 Pa |
-130 Pa |
380V/50Hz |
Ex d IIB T4 |
|
YQM-30 |
30 m³/h |
Membrane separation + condensation |
+50 Pa |
-130 Pa |
380V/50Hz |
Ex d IIB T4 |
3.2 Detailed Technical Specifications
|
Parameter Items |
YQM-8 series |
YQM-5 series |
YQM-10/30 series |
|
Gas Processing Capacity |
8 m³/h |
5 m³/h |
10~30 m³/h |
|
Start-up Pressure |
+50 Pa |
+50 Pa |
+50 Pa |
|
Shut-down Pressure |
-130 Pa |
-130 Pa |
-130 Pa |
|
Emission Concentration |
≤25 mg/L(Approximately 25 g/m³) |
≤25 g/m³ |
≤25 g/m³ |
|
Treatment Efficiency |
≥95% |
≥95% |
≥95% |
|
Power Supply |
380V 50Hz |
380V 50Hz |
380V 50Hz |
|
Motor Power |
- |
- |
1.5 kW |
|
Ambient Temperature |
- |
-20℃~50℃ |
-20℃~50℃ |
|
Explosion-proof Mark |
Ex d IIB T4 |
Ex dibⅡAT3 |
Ex d IIB T4 |
|
Parameter Items |
YQM-8 series |
YQM-5 series |
YQM-10/30 series |
3.3 Performance Indicators Description
- Processing capacity unit: m³/h (standard cubic meters per hour), representing the volume of oil-gas mixture that the equipment can process per hour.
- Start-up pressure: The equipment automatically starts when the pressure inside the oil tank reaches this value.
- Shutdown pressure: The equipment automatically stops when the pressure inside the oil tank falls below this value.
- Emission concentration: The non-methane total hydrocarbon content in the treated exhaust gas, which must meet the national standard of ≤25g/m³.
IV. Core Advantages and Features
4.1 Advanced Membrane Separation Technology
- Imported High-Quality Separation Membranes: Utilizing high-quality imported membranes with preferential air permeation, avoiding static electricity generation, ensuring a safe and reliable treatment process.
- High Separation Efficiency: Under experimental conditions, within a treatment capacity range of 2.8~4.7 m³/h, the VOCs concentration in the permeate gas remains consistently below the emission limit of 25 g/m³.
- Strong Adaptability to Pressure Fluctuations: Flow rate changes have minimal impact on the membrane system's separation performance, achieving emission standards across a wide range of treatment capacities.
4.2 Advantages of Combined Process
- Synergistic Effect of Membrane Separation + Condensation: The condensation process significantly extends the service life of the membrane and adsorbent, prolonging the overall system lifespan.
- Low Temperature and Atmospheric Pressure Operation: The entire treatment process operates at low temperature and atmospheric pressure, ensuring safety and reliability.
- Resource Recovery: High-concentration Vapor are partially liquefied naturally after being returned to the oil tank, directly generating economic benefits.
4.3 Intelligent Control System
- Automatic Start/Stop: Real-time monitoring of tank pressure; automatically starts when the set value is reached and automatically stops when the pressure falls below the shut-off value.
- PLC Fully Automatic Control: One-button start/stop, 24/7 automatic operation, no manual intervention required.
- Dynamic Pressure Management: Automatically manages minute fluctuations in tank pressure.
- Online Monitoring: Real-time monitoring of Vapor inlet pressure, temperature, flow rate, and other parameters; system operating status is clearly displayed.
4.4 Safe and Reliable Design
- Explosion-proof Rating: Ex d IIB T4 / Ex dibⅡAT3, suitable for flammable and explosive environments.
- Closed-loop Circulation: Internal circulation design prevents Vapor leakage.
- Intrinsically Safe: Membrane separation process involves no phase change and no high temperature, eliminating the risk of combustion and explosion.
4.5 Energy Saving and Environmental Benefits
- Low Operating Costs: Small footprint and low operating costs
- Direct Economic Benefits: Recovered liquid oil is returned to the oil tank, bringing significant economic benefits
- Emission Compliance: The concentration of non-methane total hydrocarbons in the treated exhaust gas is <25mg/L (approximately 25g/m³), far below national standards
- Carbon Reduction: Significantly reduces VOC emissions, contributing to the achievement of "dual carbon" goals.
V. Application Scenarios
|
Application Areas |
Description |
Recommended Model |
Application Areas |
|
Gas stations |
Suitable for gas stations with annual sales exceeding 2000 tons, for treating inhalable exhaust gases generated from storage tanks |
YQM-8 / YQM-5 |
Gas Stations |
|
Large gas stations |
Suitable for gas stations with high processing capacity |
YQM-10 / YQM-30 |
Large Gas Stations |
|
Oil storage facilities |
For exhaust gas treatment in oil depots/tank areas |
YQM-30 and above |
Oil Storage Depots |
|
Oil refining and chemical enterprises |
For Vapor recovery in loading/unloading platforms and tank areas |
High-volume customized models |
Refining Enterprises |
VI. Selection Guidelines
6.1 Selection Recommendations
|
Annual sales volume of gas stations |
Recommended Model |
Processing capacity |
Description |
|
2000-5000 tons |
YQM-5 |
5 m³/h |
Standard configuration |
|
5000-8000 tons |
YQM-8 |
8 m³/h |
Medium processing capacity |
|
Over 8000 tons |
YQM-10/30 |
10-30 m³/h |
High processing capacity, with margin for future expansion |
6.2 Process Combination Selection
|
Process combinations |
Features |
Applicable Scenarios |
Process Combinations |
|
Membrane separation + condensation |
First, membrane separation enriches Vapor , then condenses and liquefies it. |
Low-to-medium concentration Vapor , energy conservation is a priority |
Membrane Separation + Condensation |
|
Condensation + membrane separation |
First, condense to recover most of the Vapor , then perform deep treatment with membrane separation. |
High concentration Vapor , with strict emission standards |
Condensation + Membrane Separation |
|
Air cooling + membrane separation |
Combination of air-cooled pre-cooling and membrane separation. |
Water-scarce areas |
Air Cooling + Membrane Separation |
VII. Installation and Maintenance
7.1 Installation Requirements
Installed at gas stations that have already completed secondary vapor recovery system upgrades.
Requires a pre-existing foundation and installation in a well-ventilated, dedicated area away from heat sources.
Requires a 380V/50Hz power supply; power rating depends on the model.
Gas connection: DN40 or DN50 flange connection.
7.2 Routine Maintenance
|
Maintenance Items |
Cycle |
Notes |
|
Operating Parameter Check |
Daily |
Observe whether the pressure and temperature are normal. |
|
Membrane Module Performance Check |
Every 3-6 months |
Check whether the emission concentration meets the standards. |
|
Condenser Cleaning |
Every 6 months |
For air-cooled models, clean the heat sink. |
|
Membrane Module Replacement |
3-5 years |
Improve the separation efficiency as needed. |
7.3 Precautions
Inlet Vapor should be kept free of solid particles and liquid oil droplets to prevent membrane fouling.
Prevent sulfur- and silicon-containing compounds from entering the membrane system to prevent membrane poisoning.
Regularly check the vacuum pump's operating status to ensure the pressure difference across the membrane.
VIII. Policy Basis
This product meets the following standards and policy requirements:
- 《Emission Standard for Air Pollutants from Gas Stations》(GB 20952-2020): Treatment efficiency ≥95%, emission concentration ≤25g/m³
- Gas stations with annual gasoline sales exceeding 2000 tons are required to install a tertiary vapor recovery system.
- Some regions require an emission concentration ≤10g/m³ (higher configurations are available).
IX. Ordering Information
|
Project |
Contents |
|
Product Name |
Membrane separation tertiary Vapor recovery unit |
|
Production Cycle |
30-45 days (standard model) |
|
Warranty Period |
12 months |
|
After-Sales Service |
Technical support, on-site response |
Hot Tags: membrane separation tertiary vapor recovery unit, China membrane separation tertiary vapor recovery unit manufacturers, suppliers, factory, gas station hydrocarbon vapor recovery skid, gas station vapor recovery skid, gasoline station vapor recovery skid, gasoline storage tank vapor control system, gasoline vapor collection equipment, stage iii vapor recovery equipment