Condensation-type Tertiary Vapor Recovery Unit
video
Condensation-type Tertiary Vapor Recovery Unit

Condensation-type Tertiary Vapor Recovery Unit

The condensing-type tertiary Vapor recovery unit is a high-efficiency, eco-friendly device designed to address the issue of Vapor evaporation from gas station storage tanks. This product employs a multi-stage condensation process, utilizing refrigeration technology to cool the Vapor step-by-step to ultra-low temperatures. This causes the hydrocarbon components to transition directly from the gas phase to the liquid phase, enabling resource recovery. Tail gas treated by the equipment meets discharge standards, and the recovered liquid fuel can be directly reused, offering both environmental and economic benefits.

Shandong Kosman Environmental Technology Co., Ltd. is one of the leading manufacturers and suppliers of condensation-type tertiary vapor recovery unit in China. Please feel free to buy premium equipment for sale here and get pricelist from our factory. All customized products are with high quality and low price.

 

I. Product Overview

 

The condensing-type tertiary Vapor recovery unit is a high-efficiency, eco-friendly device designed to address the issue of Vapor evaporation from gas station storage tanks. This product employs a multi-stage condensation process, utilizing refrigeration technology to cool the Vapor step-by-step to ultra-low temperatures. This causes the hydrocarbon components to transition directly from the gas phase to the liquid phase, enabling resource recovery. Tail gas treated by the equipment meets discharge standards, and the recovered liquid fuel can be directly reused, offering both environmental and economic benefits.

 

This product complies with the *Emission Standard of Air Pollutants for Gas Stations* (GB 20952-2020), featuring a treatment efficiency of ≥95% and an emission concentration of ≤25 g/m³, making it a reliable choice for gas stations to achieve environmental compliance. In accordance with the latest policy requirements, gas stations with an annual gasoline sales volume exceeding 2,000 tons must complete the installation of this unit by 2027.

1c357462369a0fce0d1aabeaa9cf290e
c634e96c4e1133023af75aab76077257

 

II. Technical Principles

 

2.1 Core Technical Principles

The condensation method for Vapor recovery utilizes the principle of varying saturated vapor pressures at different temperatures. A refrigeration system cools the Vapor , bringing the hydrocarbon components to a supersaturated state so they condense into liquid for recovery.

 

Refrigeration Principle: When the compressor refrigeration system operates, high-temperature, high-pressure refrigerant gas discharged from the compressor enters the condenser, where it condenses into a high-pressure, sub-cooled liquid. It then passes through an expansion valve, undergoing throttling and pressure reduction to become a low-temperature, low-pressure gas-liquid mixture before entering the evaporator (heat exchanger). Inside the evaporator, the refrigerant absorbs heat from the Vapor stream, thereby cooling the Vapor . After fully vaporizing, the refrigerant is drawn back into the compressor's compression chamber to begin the next cycle.

 

In the condensing-type tertiary Vapor recovery system, the condensation system operates through the coordinated action of a condensation controller, an evaporator assembly, an intermediate condensation component, and a condenser assembly. Condensate circulates among the condenser assembly, the intermediate condensation component, and the evaporator assembly. Vapor enter through the inlet and are condensed by the evaporator assembly; a portion of the Vapor condenses into liquid gasoline and flows out through the oil return port, while the remaining gas exits through the gas outlet.

 

2.2 Multi-stage Condensation Process Flow

This product adopts a three-stage condensation design, featuring progressive cooling and staged recovery:

Condensation Stage

Temperature Range

Functional Description

First Stage Condensation (Pre-cooling)

3℃~5℃

Removes moisture from the gas and provides initial cooling.

Second Stage Condensation (Light Cooling)

-30℃~-40℃

Recovers most C4+ hydrocarbon components.

Third Stage Condensation (Deep Cooling)

-75℃

Deeply condenses light hydrocarbon components to ensure emissions meet standards.

Condensation Stage

Temperature Range

Functional Description

 

2.3 Workflow

Oil storage tank pressure detection (startup condition)

↓

Pressure reaches set value → System starts automatically

↓

First-stage condensation (dehumidification and pre-cooling at 3°C–5°C)

↓

Second-stage condensation (deep condensation at -30°C to -40°C) → Liquid oil recovery

↓

Third-stage condensation (ultra-low temperature condensation at -75°C) → Liquid oil recovery

↓

Tail gas heat exchange and reheating → Compliant discharge

 

Process Description:

  • Startup Trigger: The vapor recovery line connects to the recovery unit's inlet; the system starts automatically when volatile gases are generated (based on pressure signals).
  • Staged Cooling: Gas enters the refrigeration system for staged cooling and condensation, progressively reducing gas concentration.
  • Liquid Recovery: Condensed liquid oil collects in the liquid storage tank.
  • Energy Recovery: Treated low-temperature tail gas exchanges heat with the incoming waste gas via a heat exchanger to recover cooling energy and reduce energy consumption.
  • Compliant Discharge: Tail gas is reheated via heat exchange before discharge to meet standards and prevent exhaust pipe icing.

 

2.4 System Composition

This product consists of the following core components:

Component Name

Functional Description

Compressor (Refrigeration Unit)

Core of the refrigeration system; provides cooling capacity

Condenser

Condenses high-temperature, high-pressure refrigerant gas into high-pressure, subcooled liquid

Expansion Valve (Throttling Device)

Throttles and reduces pressure, bringing the refrigerant to a low-temperature, low-pressure state

Evaporator Assembly

Core heat exchange component; Vapor are cooled and liquefied here

Intermediate Condensing Assembly

Provides auxiliary condensation to enhance refrigeration efficiency

Condensation Controller

Core of the control system; regulates condensation parameters

Gas-Liquid Separator

Separates condensed liquid from uncondensed gas

Liquid Storage/Collection Tank

Temporarily stores recovered liquid oil products

Explosion-proof Control Cabinet

Features fully automatic PLC control; monitors parameters such as pressure and temperature in real time

 

The patented technology employs a structural design comprising primary, secondary, and tertiary condensation tanks and an oil-gas separation tank; these tanks are interconnected via piping to achieve efficient condensation and separation of Vapor .

 

III. Product Models and Technical Parameters

 

3.1 Standard Models

In accordance with the framework agreement requirements of major oil companies such as CNOOC, the mainstream processing capacities are 6 m³/h and 8 m³/h, with some models capable of reaching 18 m³/h.

Model

Processing Capacity

Process

Explosion-proof Rating

Power Supply

GVR4.1

18 m³/h

Cryogenic Condensation + Membrane Separation

Ex d IIB T4

380V/50Hz

Standard-06

6 m³/h

Three-stage Condensation

Ex d IIB T4

380V/50Hz

Standard-08

8 m³/h

Three-stage Condensation

Ex d IIB T4

380V/50Hz

Note: Please refer to the manufacturer's latest documentation for specific models and specifications.

 

3.2 Detailed Technical Specifications

Parameter Item

Technical Specifications

Processing Capacity

6–18 m³/h (customizable up to 30 m³/h)

Condensation Temperature

Stage 1: 3°C–5°C / Stage 2: -30°C–-40°C / Stage 3: -75°C

Vapor Recovery Rate

≥98%

Liquid Gasoline Recovery Rate

≥95%

Emission Concentration

≤10–25 g/m³ (National Standard: ≤25 g/m³)

Non-Methane Hydrocarbon (NMHC) Emission

Achievable 0.36–0.45 mg/m³

Vapor Recovery Efficiency

≥95%

Ambient Temperature

-20°C to +50°C

Explosion-proof Rating

Ex d IIB T4

Control Method

Fully automatic PLC control with touchscreen operation

Online Monitoring

Equipped with real-time online monitoring system; supports 4G IoT connectivity

 

3.3 Performance Specifications

  • Treatment Efficiency: ≥95%, meeting national standard requirements.
  • Emission Concentration: The non-methane total hydrocarbon (NMTHC) content in the treated exhaust is far below the national standard of 25 g/m³; actual levels range from 3 to 11.8 g/m³.
  • Recovery Rate: Vapor recovery rate exceeds 99%.
  • Technical Approach: Condensation is a core technology for tertiary Vapor recovery units. Pure condensation requires very low temperatures and consumes significant energy; therefore, in gas station applications, it is typically combined with adsorption or membrane separation methods. Units employing a dual-process approach-combining condensation and membrane filtration-can achieve recovery efficiencies exceeding 95%.

 

IV. Product Advantages and Features

 

4.1 Advanced Condensation Technology

  • Three-Stage Gradient Condensation: The multi-stage condensation unit operates at temperature steps of 3°C, -40°C, and -75°C, cooling progressively to enable cascaded energy utilization.
  • High-Efficiency Heat Exchanger: Equipped with an evaporator assembly, intermediate condensation module, and condenser assembly, ensuring high condensation efficiency.
  • Precise Temperature Control: The condensation controller adjusts parameters in real-time to ensure stable operation.

 

4.2 Advantages of Combined Technologies

This product can operate independently or be combined with adsorption or membrane separation methods:

Combined Process

Characteristics

Applicable Scenarios

Condensation + Adsorption

Condensation for preliminary recovery followed by adsorption for deep purification; mitigates temperature-related risks in the adsorption bed

Areas with strict emission standards

Condensation + Membrane Separation

Condensation for recovery followed by membrane separation for purification; high recovery rate

High-concentration hydrocarbon vapors; priority on energy efficiency

Pure Condensation

Direct liquefaction and recovery; straightforward results

High-concentration hydrocarbon vapors; high recovery rate requirements

 

Advantages of the combined process: Pre-cooling lowers the adsorption bed temperature, effectively eliminating the risk of high-temperature hotspots; membrane separation technology ensures excellent emission performance and high gasoline recovery efficiency.

 

4.3 Intelligent Control System

Fully automatic PLC control: One-touch start/stop and 24/7 automatic operation; no manual supervision required.

Online monitoring capabilities: Real-time monitoring of data such as tank pressure, operation cycles, run time, energy consumption, recovery volume, and carbon emission reductions.

4G IoT connectivity: Supports online monitoring functions like cloud-based maintenance and management, meeting environmental online monitoring requirements.

Remote intelligent centralized control: Enables remote management via an intelligent centralized control platform for the Stage III vapor recovery equipment.

 

4.4 High-Efficiency Recovery and Energy Saving

High recovery rate: Vapor recovery rate ≥98%; liquid gasoline recovery rate ≥95%.

Direct economic benefits: Liquid gasoline recovered via condensation can be returned directly to the storage tank for reuse, saving energy and increasing economic returns.

Cold energy recovery: Recovers cold energy via heat exchangers, reducing system energy consumption.

 

4.5 Safe and Reliable Design

Explosion-proof certification: Ex d IIB T4 rating; suitable for flammable and explosive environments.

Multiple safety protections: System features multiple safeguards to ensure overall explosion-proof integrity.

Low-temperature operation: The entire unit operates at low temperatures, eliminating combustion and explosion risks.

Closed system: Fully sealed design to prevent vapor leakage.

 

V. Application Scenarios

 

Application Area

Description

Recommended Processing Capacity

Small and Medium-sized Gas Stations

Stations with annual sales of 2,000–5,000 tons; retrofitted for Stage II vapor recovery

6–8 m³/h

Large Gas Stations

Stations with annual sales exceeding 5,000 tons

8–18 m³/h

Urban Gas Stations

Located in areas with strict environmental regulations; requires online monitoring

8–18 m³/h (optional online monitoring)

Oil Depots

Treatment of volatile Vapor emissions in depot areas

Customized high-capacity systems

 

In accordance with the latest policy requirements, gas stations with an annual gasoline sales volume exceeding 2,000 tons must complete the installation of Stage III Vapor recovery units by 2027.

 

The 2023 framework agreement of CNOOC Refining & Chemicals Co., Ltd. explicitly mandates the use of a carbon adsorption plus condensation (air-cooled) process for Vapor recovery, with treatment capacities of 6 m³/h and 8 m³/h. This indicates that condensation technology is the core process for current Stage III Vapor recovery.

 

VI. Selection Guide

 

6.1 Recommendations for Selecting Treatment Capacity

Annual Sales Volume

Recommended Processing Capacity

Recommended Process

Notes

2,000–3,000 tons

6 m³/h

Condensation + Adsorption

Standard configuration; meets basic requirements

3,000–5,000 tons

8 m³/h

Condensation + Adsorption

Includes capacity margin; complies with CNOOC requirements

5,000–8,000 tons

8–12 m³/h

Condensation + Membrane Separation

High processing capacity; higher recovery rate

Over 8,000 tons

15–18 m³/h

Condensation + Membrane Separation

Extra-large service station

 

After upgrading its tertiary Vapor recovery unit, Wuhan Petrochemical increased its processing capacity from 8 m³/h to 15 m³/h; this technical upgrade pathway can serve as a reference.

 

6.2 Comparison of Condensation Technologies

Technical Route

Minimum Temperature

Recovery Rate

Energy Consumption

Applicable Scenarios

Pure Condensation

-75°C

≥90%

Moderate

High-concentration Vapor

Condensation + Adsorption

-40°C to -75°C

≥95%

Moderate

Standard gas station applications

Condensation + Membrane Separation

-40°C to -75°C

≥98%

Relatively High

High recovery requirements and strict emission standards

 

The pure condensation method requires very low temperatures and entails high energy consumption; it is not cost-effective for gas stations and is primarily used at refineries or oil depots where large volumes of Vapor vapors are generated.

 

VII. Installation Requirements

 

7.1 Installation Conditions

  • To be installed at gas stations that have completed the retrofit for secondary vapor recovery systems.
  • Equipment foundation must be prepared; installation must take place in a dedicated, well-ventilated area away from ignition sources.
  • A 380V/50Hz three-phase power supply is required; power rating depends on the specific model.
  • Gas connection: DN40 or DN50 flange connection.
  • Exhaust outlet must be located at least 4 meters above ground level and away from areas where personnel are active.

 

7.2 Installation Precautions

  • The equipment must be installed level to ensure proper flow and recovery of condensate.
  • Electrical wiring must comply with construction standards for explosion-proof zones.
  • Adequate space must be provided around the condenser to ensure effective heat dissipation.

 

VIII. Maintenance

 

8.1 Routine Maintenance Items

Maintenance Item

Frequency

Action

Operating Parameter Check

Daily

Monitor display for temperature, pressure, and operating status

Equipment Exterior Inspection

Weekly

Check for leaks, abnormal vibration, or unusual noise

Condenser Cleaning

Monthly

For air-cooled models, clean the cooling fins to ensure effective heat dissipation

 

8.2 Periodic Maintenance

Maintenance Item

Frequency

Remarks

Emission concentration testing

Every 3 months

Test NMHC concentration at the discharge outlet to ensure compliance

Refrigeration system inspection

Every 6 months

Check refrigerant pressure and compressor operating status

System tightness test

Annually

Conduct in accordance with GB20952 requirements

Heat exchanger inspection

Annually

Check for frosting or blockages

Refrigerant replenishment

As needed

Performed by qualified personnel

 

8.3 Online Monitoring and O&M

This product is equipped with a real-time online monitoring system. The human-machine interface allows for the real-time monitoring of data such as tank pressure, operation cycles, operating duration, energy consumption, recovery volume, and carbon emission reductions. It enables real-time online monitoring of operational status and recovery data, as well as intelligent, centralized remote control, facilitating daily operation and maintenance management.

 

IX. Policy Basis

 

Standard/Policy

Number/Document

Key Requirements

Emission Standard of Air Pollutants for Gas Stations

GB 20952-2020

Treatment efficiency ≥95%; emission concentration ≤25 g/m³

Installation Scope Requirements

Environmental Protection Policy

Gas stations with annual gasoline sales exceeding 2,000 tons must complete installation by 2027

CNOOC Framework Agreement

2023 Tender Documents

Carbon adsorption + condensation (air-cooled) process; treatment capacity of 6/8 m³/h

Explosion-proof Safety Requirements

GB 3836 Series

Explosion-proof rating requirements for electrical equipment

 

Technical Specifications: In accordance with the *Emission Standards of Air Pollutants for Oil Depots*, the treatment efficiency of the vapor recovery unit must be no less than 95%, and the emission concentration must not exceed 25 g/m³.

 

XI. Technical Development Trends

 

Development and trends of condensation-based tertiary vapor recovery technology:

  • Mainstreaming of combined processes: Pure condensation methods require very low temperatures, resulting in high energy consumption and poor economic viability for gas station applications. "Condensation + Adsorption" and "Condensation + Membrane" methods have become the industry mainstream.
  • Mature and stable processes: The "Condensation + Adsorption" combination is currently the most widely used process for tertiary vapor recovery at gas stations; pre-cooling is employed to mitigate safety risks associated with adsorption bed temperatures.
  • Stricter emission standards: Application cases in Beijing show post-treatment tail gas concentrations ranging from 0.3 to 11.8 g/m³; the Jiepai Gas Station in Chengdu achieved a vapor recovery rate exceeding 99%, with an average exhaust concentration of 3.1 g/m³.
  • Intelligent upgrades: Features such as 4G IoT connectivity, cloud-based maintenance, and real-time online monitoring have become standard.
  • Due to advantages such as intuitive performance and the ability to directly recover liquid fuel, the condensation method holds a significant position in the field of vapor recovery. When combined with adsorption or membrane separation methods, it can achieve the dual goals of ultra-low emissions and high recovery rates.

 

XII. Ordering Information

 

Item

Details

Product Name

Condensation-based Tertiary Oil & Gas Recovery Unit

Processing Capacity

6–18 m³/h (customizable up to 30 m³/h)

Condensation Temperature

-40°C to -75°C (customizable)

Production Lead Time

30–45 days (standard models)

Warranty Period

12 months (from the date of acceptance)

Optional Configurations

Online monitoring system, 4G IoT module, cloud management platform

After-sales Service

Technical support; response within 48 hours

 

Specific prices and delivery times are subject to actual quotation.

 

Hot Tags: condensation-type tertiary vapor recovery unit, China condensation-type tertiary vapor recovery unit manufacturers, suppliers, factory, carbon adsorption gasoline vapor recovery system, fuel station vapor control system, gas station hydrocarbon vapor recovery skid, gasoline service station vapor control system, gasoline station vapor recovery skid, gasoline vapor collection equipment